The steam container is a top-level config.txt file entry used by Steam Enginespec assets.
Supported Tags
The Steam container supports the following tags. Each tag is show here with its default value.
steam { boiler-volume 10.0 burn-rate 0.5 burn-rate-idle 0.01 firebox-heating-surface-area 20 firebox-efficiency 0.75 firebox-thermal-conductivity 10 firebox-plate-thickness 0.016 fuel-energy 27912000 fuel-specific-heat-capacity 1260 initial-boiler-temperature 373 max-coal-mass 1000 ideal-coal-mass 500 min-fire-temperature 500 max-fire-temperature 1300 minimum-volume 8.0 maximum-volume 9.0 fusible-plug-volume 7.5 boiler-heat-loss 2.0 piston-angular-offsets 0.0174,1.5254,3.0333,4.5413 piston-volume-min 0.0272 piston-volume-max 0.1505 piston-area 0.1734 safety-valve-low-pressure 1653 safety-valve-low-flow 0.05 safety-valve-high-pressure 1684 safety-valve-high-flow 0.1 shovel-coal-mass 5.0 water-injector-rate 3.0 water-injector-rate2 3.0 boiler-efficency-idle 0.75 boiler-efficency 0.4 boiler-efficency-min 0.25 speed 15.0 cutoff 0.4 blower-effect 0.5 blower-max-flow 2.5 starting-coal 500 starting-water 7500.0 starting-boiler-steam 10.0 steam-chest-volume 0.1233 steam-chest-max-flow 25.0 valve-lap-percent 0.05 hand-brake-max-force 1000 super-heating-constant 100 tractive-effort-constant 0.8 number-cylinders 2 number-power-strokes 2 legacy-piston-count 4 }
boiler-volume
- Type: Decimal
- Desc: Volume in Metres cubed. This is the total capacity of the boiler.
burn-rate
- Type: Decimal
- Desc: How much coal (kg) is consumed per second when the loco is operating at the test parameters?
burn-rate-idle
- Type: Decimal
- Desc: How much coal (kg) is consumed per second when the loco is idle, purely to keep the fire burning?
firebox-heating-surface-area
- Type: Decimal
- Desc: Surface area of the firebox used for heating water. In practice, most of the water heating is done through the firebox, not through the tubes. For this reason, the surface area quoted should be that of all used sides of the firebox - normally front, back, top, left, right. Larger areas result in more firebox to boiler heat transfer - both cooling the fire and heating the water.
firebox-efficiency
- Type: Decimal
- Desc: Ratio (0.0 -> 1.0). How efficient is the firebox - how much of the fire output is captured and used, and how much is lost? Higher numbers here mean the fire heats up faster, and stays hotter longer when you are trying to cool it down after a run. Lower numbers result in a more lethargic fire which takes longer to heat up, and will cool more quickly.
firebox-thermal-conductivity
- Type: Decimal
- Desc: Technically watts per metre kelvin, but real numbers are no good here - many factors mean a steam loco is far from an ideal heat conductor that the equations are based around. 10 seems to be a good number, found by experimentation. A higher number here will mean more heat transfer from the fire to the boiler - resulting in higher pressure but also less fire temperature. Lower numbers will result in more fire temperature, but less heating.
firebox-plate-thickness
- Type: Decimal
- Desc: Thickness of firebox plate in metres.
fuel-energy
- Type: Decimal
- Desc: Joules per kilogram. Amount of energy (joules) that can be released by burning 1 kg of the fuel.
fuel-specific-heat-capacity
- Type: Decimal
- Desc: Joules per kilogram kelvin. Amount of energy (joules) needed to raise the temperature of 1 kg of the fuel substance by one degree kelvin.
initial-boiler-temperature
- Type: Decimal
- Desc: Degrees kelvin. This value will determine whether the engine is 'ready to go' or needs 'warming up' prior to a run when first placed.
max-coal-mass
- Type: Decimal
- Desc: Maximum amount (kg) of coal it's possible to cram in the firebox, before it starts falling out.
ideal-coal-mass
- Type: Decimal
- Desc: Ideal amount (kg) of coal to have in the firebox for optimal burning. This value will appear as "100%" on the interface, and will burn the best.
min-fire-temperature
- Type: Decimal
- Desc: Degrees K. A higher value here makes the loco 'wake up' quicker, but too high a value will make it build pressure even when left idle.
max-fire-temperature
- Type: Decimal
- Desc: Degrees K. Lowering top end fire temperature will have the effect of limiting both top end boiler pressure and maximum water heating ability when working hard.
minimum-volume
- Type: Decimal
- Desc: Volume in Litres. This is the amount of water in the boiler that corresponds to the bottom of the sight glass - 0% on the interface.
maximum-volume
- Type: Decimal
- Desc: Volume in Litres. This is the amount of water in the boiler that corresponds to the top of the sight glass - 100% on the interface. It should be above the 'minimum volume'.
fusible-plug-volume
- Type: Decimal
- Desc: Volume in Litres. This is the amount of water in the boiler at which point the fusible plugs will kick in. It should be below the 'minimum volume'.
boiler-heat-loss
- Type: Decimal
- Desc: TBD
piston-angular-offsets
- Type: Decimal Array
- Desc: Values are specified in radians. Amount of wheel rotation required to rotate each piston to maximum travel from starting position. Will depend on how the valve gear has been animated in max. One value per piston.
piston-volume-min
- Type: Decimal
- Desc: clearance volume of a piston - i.e. the volume at minimum travel. This value greatly affects the level of front-end power available to a specific loco.
piston-volume-max
- Type: Decimal
- Desc: Total volume of a piston at maximum travel - i.e. the swept volume (stroke*area) plus the clearance volume.
piston-area
- Type: Decimal
- Desc: Surface area of the piston (metres squared).
safety-valve-low-pressure
- Type: Decimal
- Desc: Pressure (absolute, and in kPa) at which the low pressure safety valve will blow.
safety-valve-low-flow
- Type: Decimal
- Desc: Kilograms per second of steam that escape through the low pressure safety valve. Note: Too high a value will result in a 'sawtooth' boiler pressure, and repeated short hisses from the safety valve.
safety-valve-high-pressure
- Type: Decimal
- Desc: Pressure (absolute, and in kPa) at which the high pressure safety valve will blow.
safety-valve-high-flow
- Type: Decimal
- Desc: Kilograms per second of steam that escape through the high pressure safety valve. Remember that both valves will be open at this point.
shovel-coal-mass
- Type: Decimal
- Desc: How much coal does the fireman move each time he shovels?
water-injector-rate
- Type: Decimal
- Desc: litres of water moved into the boiler per second through the first injector when fully on.
water-injector-rate2
- Type: Decimal
- Desc: litres of water moved into the boiler per second through the second injector when fully on.
boiler-efficency-idle
- Type: Decimal
- Desc: Ratio (0.0 -> 1.0). Maximum efficiency of boiler - e.g. when loco idle.
boiler-efficency
- Type: Decimal
- Desc: Ratio (0.0 -> 1.0). Efficiency of boiler when working at test parameters.
boiler-efficency-min
- Type: Decimal
- Desc: Minimum boiler efficiency. Calculated efficiency will not fall below this value.
speed
- Type: Decimal
- Desc: Speed of test run on which test parameters are based.
cutoff
- Type: Decimal
- Desc: Ratio (0.0 -> 1.0). Position of cutoff control for test run.
blower-effect
- Type: Decimal
- Desc: Multiplier. Sets the effectiveness of the blower. Value is the draft effect of working the loco at the test parameters compared with running the blower at maximum boiler pressure but the loco otherwise idle.
blower-max-flow
- Type: Decimal
- Desc: Kilograms per second of steam used by blower at max boiler pressure and max setting.
starting-coal
- Type: Decimal
- Desc: Kilograms of coal to start with in the firebox. Ideal value will be used if this is not present.
starting-water
- Type: Decimal
- Desc: Volume of water (in Litres) to start with in the boiler. 50% level (halfway between 'max' and 'min' on the sight glass) will be used if this is not present.
starting-boiler-steam
- Type: Decimal
- Desc: Amount of steam to start with in the boiler. If this is too high, a false 'high pressure' will be reported at initial startup (but working the loco will reduce it). If it is too low, the boiler will boil water to build pressure, so using a low value (maybe even zero?) is suggested.
steam-chest-volume
- Type: Decimal
- Desc: Volume (metres cubed) of the steam chest.
steam-chest-max-flow
- Type: Decimal
- Desc: Max flow (kilograms per second) of steam from boiler to steam chest with regulator fully open.
valve-lap-percent
- Type: Decimal
- Desc: Ratio (0.0 -> 1.0)
hand-brake-max-force
- Type: Decimal
- Desc: Maximum force exerted by handbrake.
super-heating-constant
- Type: Decimal
- Desc: Degrees (kelvin) to increase temperature of steam between boiler and steam chest. High superheat results in more power at the front end.
tractive-effort-constant
- Type: Decimal
- Desc: TBD
number-cylinders
- Type: Integer
- Desc: Number of cylinders.
number-power-strokes
- Type: Integer
- Desc: Number of power strokes per revolution. Two is by far the most common number, but this can be other numbers in extreme cases.
legacy-piston-count
- Type: Decimal
- Desc: Used for loading old (TRS2006) saved sessions. An omission in the TRS2006 save format causes a loco with a different number of pistons not to load properly. The number of pistons often needs to be changed when updating old enginespecs, as previously engines had to have twice as many single acting pistons, rather than the correct number of double acting pistons as they do now. This value is to record the old number of pistons so that old sessions can still be loaded.
Example steam container
TBD